Peking Union Medical College HospitalResearch Archive

Peking Union Medical College Hospital connects in-hospital management and patient guidance with dual-track digital employees

Healthcare and life sciencesHospital operations and patient guidanceProduction deploymentHospital operationsEnterprise knowledge baseMulti-agentHITLDigital humanSystem integration

Chinese original · AI organized · Customer co-creation

In-depth case · Case quick read

Case Overview

Business Problem

Administrative information is scattered across policies, SOPs, and multiple departments, and patient guidance is constrained during peak hours and non-working hours; the same knowledge must also remain consistent across mobile phones, WeChat official accounts, self-service kiosks, and on-site digital humans.

Publicly disclosed AI solutions

Chinese original · AI-compiled. Peking Union Medical College Hospital Xidan Campus splits in-hospital management and patient services into two sets of digital employees: the in-hospital side is privately deployed and connected to WeLink, while the patient side is coordinated by a cloud medical model and a local knowled…

Core Engineering Findings

Engineering Analysis by This Library

Treat the hospital Agent as a versioned knowledge service, not a universal chat entry point

If only a unified RAG is implemented, the most likely problems are permission overreach, expired answers, and drift in standards across multiple terminals.

Original disclosure · View basis

Technical Architecture

Public solution summary

The original text discloses fully private deployment for internal management, with the vector database and computing power kept in-hospital and unified authentication via WeLink; the patient side adopts a dual-core approach of a cloud medical large model and a local knowledge base, local-first with cloud fallback, mult…

View the complete architecture and reference data flow

Key engineering trade-offs

Engineering Analysis by This Library

Split deployment surfaces by in-hospital private and patient services, and design an operational closed loop around authoritative sources, knowledge versions, locality filtering, and manual escalation.

Security and correctness are clearer, but it entails the cost of dual-track knowledge synchronization, terminal caching, and continuous review.

In-depth Technical Analysis

Outcomes and Verification Boundaries

Production deployment

Project self-report: more than 2,200 in-hospital knowledge base documents, and answer accuracy of over 95% in related scenarios; on the patient side, more than 1,100 Q&A items, about 1,500 consultations per month on average, 10% during non-working hours, and a 5% decrease in the number of receptions at the manual triage desk compared with before launch; the digital human in-hospital Q&A comparison score is 86.9. None have independent acceptance.

Original text verified · Public cases · Benefits not independently accepted

The source is the CHIMA typical case collection; the metrics are the project party's public statements, and no independent acceptance materials have been seen; 95% refers only to the answer accuracy rate in related scenarios, and the 86.9 points come from the in-hospital guide comparison and cannot be extrapolated to c…

Complete results criteria and applicable boundaries
In-depth Technical Analysis Architecture, Trade-offs, and Transfer Conditions
01

Business Background and Process

Research Analysis

Administrative information is scattered across policies, SOPs, and multiple departments, and patient guidance is constrained during peak hours and non-working hours; the same knowledge must also remain consistent across mobile phones, WeChat official accounts, self-service kiosks, and on-site digital humans.

Role
In-hospital employees, administrative departments, customer service center, outpatient nurses, patients, nursing knowledge maintenance team, hospital IT team, and partner technology team.
Reproduction scope
The research scope is limited to hospital administrative management and patient service Q&A and does not extend to clinical diagnosis, prescriptions, or automatic execution of high-risk medical actions.
  1. 1Collect policies, SOPs, customer service recordings, and service guides
  2. 2Expert review and structuring into in-hospital and patient knowledge bases
  3. 3Select the private/patient service path through identity or terminal context
  4. 4Prioritize retrieval from local knowledge and call the cloud model within the permitted scope
  5. 5Return Q&A, process, or medical guidance and record feedback
  6. 6Nursing and administrative teams review unmatched and deviating cases and update knowledge

Engineering Problems and Transferable Lessons

Key Engineering Insight
Original disclosureSource verifiedweb-93ca455258859187513be5ed-deployment
Special Issues
The same hospital simultaneously has sensitive in-hospital policies, rapidly changing shift schedules, and low-risk patient Q&A, with different data boundaries and timeliness requirements.
Why Ordinary Architecture Is Not Enough
If only a unified RAG is implemented, the most likely problems are permission overreach, expired answers, and drift in standards across multiple terminals.
Key technical choices
Split deployment surfaces by in-hospital private and patient services, and design an operational closed loop around authoritative sources, knowledge versions, locality filtering, and manual escalation.
Costs and trade-offs
Security and correctness are clearer, but it entails the cost of dual-track knowledge synchronization, terminal caching, and continuous review.
Failure conditions
The main failure conditions are leakage of private questions, expiration of time-sensitive data, failure to transfer medical treatment questions to humans, and conflicting answers across terminals.
Transferable experience
Transferable to the dual portals of employee services and public services in large institutions, starting with low-risk administrative questions to establish versioning and feedback mechanisms.

Public materials support the problem background; technical supplements are engineering inferences by this library. Related original text:

Original disclosureSource verifiedweb-93ca455258859187513be5ed-iterationEngineering ProjectionInsufficient evidenceweb-93ca455258859187513be5ed-insight
03

Technical Architecture and Data Flow

Original text / solution listed separately

Original architecture summary

The original text discloses fully private deployment for internal management, with the vector database and computing power kept in-hospital and unified authentication via WeLink; the patient side adopts a dual-core approach of a cloud medical large model and a local knowledge base, local-first with cloud fallback, multiple terminals sharing the same knowledge base, and multi-model validation and manual review added in key scenarios.

The original text discloses the in-hospital private vector database/computing power, WeLink unified authentication, patient-side cloud model and local knowledge base, multi-terminal shared database, multi-model validation, and manual review. The specific model routing algorithm, retrieval parameters, permission matrix, and failover are not disclosed; the following data flow and reproduction steps are design suggestions from this library.

Suggested Architecture for Reproduction

The following is the research design and does not represent the complete implementation of the enterprise's internal system.

  1. 1
    Identity and scenario routing

    It is recommended to first determine the visible knowledge scope based on WeLink identity or patient terminal, and prohibit in-hospital private content from entering the patient-side cloud path.

  2. 2
    Timeliness and locality filtering

    Filter by campus, date, and knowledge effective period before retrieval; read time-sensitive data from authoritative sources rather than hard-coding it in the vector database.

  3. 3
    Retrieval and controlled generation

    Local knowledge first; refuse or transfer to a human for low-confidence or high-risk questions; permitted cloud supplementation must remove restricted data and log the call.

  4. 4
    Feedback loop

    Save the match basis, score, error correction, and manual transfer result; publish a new version after review by the knowledge owner, with rollback capability.

Suggested Data and System Interfaces

Business ObjectJoin key / criteriaSuggested SourcesPurpose in the process
In-hospital policy and process entriesDocument ID, version, effective/expiration time, responsible department, applicable campusDocument control system, WeLink, service guides, and telephone directoryProvide employees with traceable Q&A answers that have clear validity boundaries
Patient service Q&AQuestion ID, knowledge version, campus, service scenario, reviewerCustomer service call recordings transcription, hospital official website, patient knowledge baseSupport triage consultation, medical guidance, and health education, and record unmatched cases
Shift and timetable informationDate, campus, department/doctor/shift, update timeDoctor shift schedules, self-built time source, shuttle bus and cafeteria data sourcesAnswer time-sensitive questions such as today's/next shift and avoid outdated information
Q&A feedback eventSession ID, question, matched document, score, error-correction status, manual transfer resultAgent logs, satisfaction, and ticketing systemWeekly review of knowledge gaps, deviations, and high-risk answers
04

Key design trade-offs

Research Analysis

Why not let the in-hospital and patient sides share a single cloud-based Q&A system?

Suggested choice:Split into a fully private in-hospital path and a dual-core patient service path based on data sensitivity, while sharing reviewed public knowledge.

Basis for judgment: In-hospital administrative data and user information require stricter access control, while the patient side requires multi-terminal reachability and localized services.

Costs and boundaries: Dual-track deployment increases the cost of knowledge synchronization, monitoring, and version governance; drift in standards between the two sides must be avoided.

How are rapidly changing facts such as shuttle buses, menu items, and clinic schedules handled?

Suggested choice:Treat the time source and shift data as structured authoritative sources, read them when answering, and display the update time.

Basis for judgment: The main risk of such questions is knowledge expiration, not the language model's expressive ability.

Costs and boundaries: Stable interfaces, cache invalidation and data owners are required; when interfaces fail, the system must degrade rather than guess.

When must the patient side transfer to a human?

Suggested choice:Set up manual escalation for symptom judgment, diagnostic decisions, low confidence, knowledge conflicts, and repeated follow-up questions.

Basis for judgment: The case demonstrates guidance and health education, which is not equivalent to clinical diagnostic capability.

Costs and boundaries: A more conservative threshold will lower the automation rate but can safeguard the medical risk boundary.

Engineering Failure Conditions

Exceptions and Degradation

In-hospital private questions routed to the patient-side cloud model

Reject the call at the routing layer and log a security event, returning a controlled prompt or transferring to an in-hospital human.

Shift, shuttle bus, or menu data source times out or the version expires

Display the last update time and refuse to give a definitive time, providing an authoritative query entry point.

The same question yields different answers on mobile phones, WeChat official accounts, and digital human terminals

Suspend conflicting knowledge, compare versions and caches, and roll back to the most recently reviewed version.

When a patient raises diagnosis, medication, or emergency questions

Stop general Q&A, prompt emergency medical care or transfer to a human, and do not extend guide knowledge into medical advice.

When it is suitable for adoption, and how value is measured

Research Recommendations by This Library
Data and Organizational Prerequisites
The owners and update frequencies of in-hospital policies, SOPs, telephone directories, scheduling and visit knowledge must be clarified; unified identity access, traceable error-correction records, patient-side content review, and private/cloud data boundaries must be implemented first.
Division of labor among AI, rules and humans
AI handles retrieval, intent routing, standard Q&A, and process guidance; rules handle identity, time validity, locality priority, and high-risk content interception; nursing and administrative teams maintain knowledge, review deviations, and handle escalations.
Conditions not recommended for adoption
If policies lack version numbers and owners, time-sensitive data such as shift schedules cannot be synchronized, patient questions cannot be transferred to humans, or administrative Q&A is directly extended into diagnostic advice, then coverage should not be expanded.
Investment and Ongoing Costs
One-time investment includes data cleansing, private deployment, unified authentication, multi-terminal access, and baseline testing; ongoing investment includes weekly Q&A review, knowledge revision, model and prompt updates, permission audits, and terminal operations and maintenance.
Value and evaluation criteria
Measure separately the in-hospital scenario hit rate, error/expired answer rate, manual consultation transfer volume, non-working-hours coverage, patient-to-human transfer rate, and knowledge update latency, avoiding reliance on conversation counts alone.
Suggested First Step
Start with low-risk in-hospital questions such as shuttle buses, cafeteria, and reimbursement processes; build a versioned knowledge list with owners; run a two-week shadow test with real unmatched questions before enabling write access or patient-side capabilities.
Research Appendix Complete evidence, metric criteria and research materials
02

Original disclosure and evidence boundaries

Original text verified

Original title: Peking Union Medical College Hospital: Research and Application Demonstration of Hospital Management Digital Employee Agents

Original summary: Chinese original · AI-compiled. Peking Union Medical College Hospital Xidan Campus splits in-hospital management and patient services into two sets of digital employees: the in-hospital side is privately deployed and connected to WeLink, while the patient side is coordinated by a cloud medical model and a local knowledge base, continuously maintained through satisfaction, error correction, weekly nursing team reviews, and manual review.

The project uses the Xidan Campus of Peking Union Medical College Hospital as a pilot; in January 2025, "Xiyuan Baishitong" was launched on the hospital's WeLink, and internal management adopts private deployment.

Original location: Project introduction; construction and development · implementation and iterative optimization of internal management ↗

The in-hospital knowledge base integrates more than 2,200 documents, covering policies, processes, shuttle buses, cafeteria, and clinic schedule information; the source states that the answer accuracy rate in related scenarios reaches above 95%.

Original location: Project introduction; application effects · significant results in improving quality and efficiency of internal management ↗

The patient-side digital human "Xiaohui" was activated in August 2025, uses a cloud knowledge base and locality-priority strategy, covers more than 1,100 common Q&A entries, and provides triage, consultation, guidance, and health education.

Original location: Project introduction; construction and development · expansion of patient services ↗

The source reports that the patient side averages about 1,500 consultations per month, non-working hours account for 10%, daily consultations account for about 8% of total outpatient guide volume, and manual guide desk reception volume decreased by 5% compared with before activation.

Original location: Application effects · Dual improvement in patient service capability and medical experience ↗

The project has established mechanisms for satisfaction, issue correction, weekly reviews by the nursing team, multi-model validation and manual review, and continues to iterate in phases from October 2024 to the present.

Original location: Construction and development · Four-phase process ↗
Metric Definitions

Project self-report: more than 2,200 in-hospital knowledge base documents, and answer accuracy of over 95% in related scenarios; on the patient side, more than 1,100 Q&A items, about 1,500 consultations per month on average, 10% during non-working hours, and a 5% decrease in the number of receptions at the manual triage desk compared with before launch; the digital human in-hospital Q&A comparison score is 86.9. None have independent acceptance.

Disclosure Boundaries

The source is the CHIMA typical case collection; the metrics are the project party's public statements, and no independent acceptance materials have been seen; 95% refers only to the answer accuracy rate in related scenarios, and the 86.9 points come from the in-hospital guide comparison and cannot be extrapolated to clinical diagnostic quality or hospital-wide business benefits.

Delivery process

Customer co-creation

The case collection explicitly states cooperation between the hospital and a large internet company and discloses needs research, data collection, platform development, in-hospital launch, patient-side expansion, and continuous iteration starting from October 2024; it does not disclose the specific supplier team division of labor, contract acceptance, or handover terms, and FDE participation is not inferred from this. Delivery method basis

Project disclosure 5 / 7 items. Vendor methods are labeled separately. Not disclosed means the current verification materials do not explain it.

Delivery TeamNot disclosed

The original text only states cooperation between the hospital and a large internet company and does not disclose the specific team sizes, roles, or on-site arrangements of either party.

Customer participation and co-creationProject disclosure

The hospital conducts needs research, data collection, knowledge review, and iterative feedback around administrative and patient service needs, while the technology party co-builds based on the HiAgent platform.

Original location: Construction and development · Preliminary preparation and iteration phase
Project durationProject disclosure

Preparation from October to December 2024; in-hospital implementation and iteration from January to April 2025; expansion of patient services from May to August 2025; continuous optimization and preparation for rollout from September 2025 onward.

Original location: Construction and development · Four-phase timeline
Data and System IntegrationProject disclosure

The in-hospital side connects to WeLink unified authentication, private vector database, and computing power; the patient side connects to WeChat official accounts, self-service kiosks, outpatient terminals, shift schedules, and official website specialty information.

Original location: Key technology; Construction and development · Patient service expansion
Iteration and operationsProject disclosure

Supplement knowledge through satisfaction, question error correction, customer service tickets, and weekly nursing team reviews, with multi-model validation and manual review added in key scenarios.

Original location: Construction and development · Continuous optimization phase
Acceptance and effectiveness evaluationProject disclosure

The original text discloses the in-hospital scenario accuracy rate and comparison testing against human guides, but there are no contract acceptance or independent third-party acceptance materials.

Original location: Application effects; Table 1 Guide Q&A capability comparison
Handover and Capability TransferNot disclosed

The original text discloses a standardized plan and rollout preparation but does not explain the handover arrangements for technical assets, training, operations responsibilities, and exit criteria.

Delivery materials verification date: 2026-11-04

Metrics and Measurement Definitions

Retain original criteria

"Source verified" only means the public disclosure can be located; it does not mean business results have undergone independent third-party acceptance. Unknown items remain "not disclosed in the original text."

Answer accuracy rate in related scenarios

Results reported by the source

Above 95% %

Original disclosureSource verifiedweb-93ca455258859187513be5ed-internal
Baseline
The pre-iteration values are not disclosed in the original text
Comparison Period
After iteration from February to April 2025
Measurement Scope
Related in-hospital scenarios such as policies, processes, shuttle buses, and cafeteria
Limitations
Sample, annotation, and confidence interval are not disclosed.
Source:Construction and development · Internal management implementation and iterative optimization

Change in manual guide desk reception volume

Results reported by the source

-5 %

Original disclosureSource verifiedweb-93ca455258859187513be5ed-patient
Baseline
Manual guide desk reception volume before activation
Comparison Period
Before and after activation of the patient module; specific months not disclosed
Measurement Scope
Outpatient manual guide desk reception volume
Limitations
Changes in foot traffic, seasonality, and causal controls are not disclosed; it cannot all be attributed to the digital human.
Source:Application effects · Patient services

In-hospital comparison score of digital human Q&A capability

Benchmark/performance sample

86.9 points (out of 100)

Original disclosureSource verifiedweb-93ca455258859187513be5ed-patient
Baseline
The original table of the human guide distribution is not fully expanded
Comparison Period
In-hospital comparison testing before case release
Measurement Scope
Q&A capability PK between in-hospital human guides and the digital human "Xiaohui"
Limitations
The question set, scoring dimensions and errors are not disclosed and cannot be equated with clinical quality.
Source:Construction and development · Continuous optimization phase; Table 1
Research Verification Materials

Engineering Verification Status

Type, scope, and execution are recorded separately

Verification has no automatic progression; passing limited synthetic samples does not prove the model, the complete system, or customer production acceptance. Public business outcomes are shown only according to the original evidence.

This section is an engineering reference design, and there is no end-to-end execution record in this library yet.

Test Plan · Not yet executed

Verification scope
The research scope is limited to hospital administrative management and patient service Q&A and does not extend to clinical diagnosis, prescriptions, or automatic execution of high-risk medical actions.
Input Data
Synthetic, public, or authorized data; specific experimental inputs are still to be prepared.
Expected output
All answers are traceable to a valid version; high-risk or evidence-lacking questions do not generate definitive answers.;Zero permission overreach, knowledge updates are rollback-capable, and unmatched and error-correction cases each have an owner.;Same question and same version across terminals; medical treatment questions reliably transferred to humans; usable fallback available during non-working hours.
Actual output
Not yet executed, no actual output
Execution Time
Not yet executed; collection time is not used as a substitute
Limitations and failure notes
Phased reproduction and evaluation are planned and cannot be used to prove that an actual system is already running.
05

Phased reproduction path

The complete solution has not yet been executed

Use synthetic, public or authorized data. The following is a follow-up plan; if there is a rule check above, it only proves the samples it explicitly lists and does not mean complete reproduction has been completed.

  1. 1

    Low-risk in-hospital shadow validation

    Organize versioned knowledge and historical real questions for three administrative scenarios, and compare hits, citations, and expired answers offline.

    Planned deliverables:Knowledge list, responsibility matrix, baseline question set, and error classification

    Suggested acceptance conditions:All answers are traceable to a valid version; high-risk or evidence-lacking questions do not generate definitive answers.

  2. 2

    Controlled pilot

    Connect test identity, time source, and ticketing system; open only to a small group of employees and record manual transfers.

    Planned deliverables:Read-only pilot, feedback panel, rollback and audit records

    Suggested acceptance conditions:Zero permission overreach, knowledge updates are rollback-capable, and unmatched and error-correction cases each have an owner.

  3. 3

    Patient-side separate expansion

    After medical and nursing review, publish low-risk medical guidance to an independent patient knowledge base and terminals.

    Planned deliverables:Patient-side knowledge package, manual escalation process, and multi-terminal consistency checks

    Suggested acceptance conditions:Same question and same version across terminals; medical treatment questions reliably transferred to humans; usable fallback available during non-working hours.

06

Evaluation and Failure Handling

Proposed Solution to Be Verified

The evaluation targets are recommended thresholds and need to be adjusted based on risk and baseline; there are currently no measured results.

MetricsMeasurement MethodSuggested Judgment Conditions
Valid version hit rateSample historical questions by scenario and campus, and check whether answer citations point to currently effective knowledge.Pilot goals should be set by the hospital; erroneous versions and unsupported answers should be counted separately, not just aggregated into an accuracy rate.
High-risk escalation recallConstruct questions on medical treatment, permission overreach, conflicting knowledge, and low confidence, and check whether they are refused or transferred to a human.High-risk samples must not be automatically given definitive diagnostic and treatment conclusions, and missed referrals to manual review must be reviewed case by case.
Transfer to and return from manual consultationCompare manual consultation volume before and after launch in the same scenario, while also counting the proportion of returns to manual due to incorrect or incomplete answers.While reducing repetitive consultations, the return rate and complaints should not worsen; do not equate conversation volume with value.
Knowledge update latencyTimed from the release of a policy or shift change to the new version being retrievable on each terminal.Set thresholds according to business timeliness; expired content cannot continue to be matched after the threshold.

Questions to confirm in the next round

  • What are the sample size, annotation method, and confidence interval for the 95% accuracy rate?
  • What are the question set, scoring dimensions, and manual baseline distribution for the 86.9-point in-hospital guide comparison?
  • How is sensitive information identified and de-identified before the cloud model fallback?
  • When rolling out across multiple campuses, who approves knowledge inheritance, locality coverage, and version conflicts?

Verification Records and Items to Be Confirmed

2026-11-04

Full-text verification of deployment, timeline, knowledge operations, business metrics, and delivery boundaries; no system reproduction was performed.

The full CHIMA case text is readable; the original source attributes it to the CHIMA 2026 Collection of Typical Cases of Emerging Technology Innovation and Application in Hospitals.

  • All business metrics retain their original units, scope, and the project party's self-reported boundaries.
  • No independent acceptance materials were found; businessOutcomesIndependentlyAccepted remains false.
  • Neither field development engineers nor Forward Deployed Engineers are disclosed; FDE is not explicitly indicated.
  • No new or run rule tests, model experiments, or end-to-end reproduction.
View all assertions · 5 items
Original disclosure · Source verified · web-93ca455258859187513be5ed-deployment

Complete assertion: In-hospital management adopts fully private deployment with unified authentication via WeLink; patient services adopt a dual-core approach of a cloud medical model and a local knowledge base, local-first with cloud fallback.

Verification method
Original materials verification
Last Verified
2026-11-04
Applicable boundaries
The source is the project case collection; network topology, model routing, and de-identification implementation are not disclosed.
Related cases
Peking Union Medical College Hospital connects in-hospital management and patient guidance with dual-track digital employees
Source location:Key technology · Differentiated deployment and multi-agent collaboration technology
Original disclosure · Source verified · web-93ca455258859187513be5ed-internal

Complete assertion: "Xiyuan Baishitong" launched in January 2025 and integrates more than 2,200 in-hospital documents; the source states that the answer accuracy rate for related scenarios reaches above 95%.

Verification method
Original materials verification
Last Verified
2026-11-04
Applicable boundaries
The accuracy question set, annotation, and statistical methods are not disclosed and cannot be extrapolated to all in-hospital questions.
Related cases
Peking Union Medical College Hospital connects in-hospital management and patient guidance with dual-track digital employees
Source location:Project introduction; application effects · internal management
Original disclosure · Source verified · web-93ca455258859187513be5ed-patient

Complete assertion: The patient digital human was activated in August 2025 and integrates more than 1,100 Q&A entries; the source reports an average of about 1,500 consultations per month, with non-working hours accounting for 10%, and manual guide desk reception volume down 5%.

Verification method
Original materials verification
Last Verified
2026-11-04
Applicable boundaries
The project party's public statements; no independent acceptance; baseline period and seasonality are not disclosed.
Related cases
Peking Union Medical College Hospital connects in-hospital management and patient guidance with dual-track digital employees
Source location:Application effects · Dual improvement in patient service capability and medical experience
Original disclosure · Source verified · web-93ca455258859187513be5ed-iteration

Complete assertion: The project updates knowledge through satisfaction, issue correction, customer service tickets and weekly reviews by the nursing team, and adds multi-model validation and manual review in key scenarios.

Verification method
Original materials verification
Last Verified
2026-11-04
Applicable boundaries
The trigger conditions and service levels for manual review are not disclosed.
Related cases
Peking Union Medical College Hospital connects in-hospital management and patient guidance with dual-track digital employees
Source location:Construction and development · Continuous optimization and rollout preparation phase
Engineering Projection · Insufficient evidence · web-93ca455258859187513be5ed-insight

Complete assertion: The core engineering control points of this scenario should be knowledge versions, timeliness, campus locality, and patient risk triage, rather than simply expanding the number of models or multi-agents.

Verification method
No experimental validation yet
Last Verified
Not yet verified or executed
Applicable boundaries
Research judgment of this library, not yet reproduced or accepted in the case system.
Related cases
Peking Union Medical College Hospital connects in-hospital management and patient guidance with dual-track digital employees

Review record: web-93ca455258859187513be5ed-audit · Full-library review records

Original research judgment and attribution

The most worthwhile aspect of this case to study is how differentiated deployment and unified knowledge operations allow in-hospital administrative Q&A and patient guidance to operate within different safety boundaries, rather than treating the number of multi-agents itself as value.

Research compilation and solution analysis: Zuren Zhao · AI-assisted compilation. Original case delivery belongs to the original enterprises and service providers.

China Hospital Information Management Association (CHIMA) · Original text verified · Verification time 11/05, 05:12 AM(Beijing time)

Read the original source